The splash guards installed on these fryers are not high enough to provide adequate protection between the fryer and grill. If there is less than 16” between the fryer and open flames, an 8-inch tall metal baffle, splash guard, or tempered glass plate should be installed between the fryer and the open flames.

Damaged smoke detectors can be just as dangerous as not having one. Submit recommendations for inspection and repair of any detectors observed in less than good condition.

This ice machine was observed to be leaking, and water was pooling in the hallway. Pooling water not only presents a slip and fall hazard, but can also present a risk of shock if near electrical power.

Always point out missing smoke detectors. The base won’t save a life